Skip to Content
This documentation is provided with the HEAT environment and describes this HEAT instance.

Troubleshooting the Open DIS module

No PDUs are ever received

Cause. Either nothing on the network is sending DIS traffic to the configured port/mode, or UdpPort was changed away from its default (3000) without also updating the workstation firewall rule this module’s network.listen capability is scoped to.

Fix. Confirm a DIS source is actually broadcasting to, or multicasting on, the configured UdpPort and NetworkGroupAddress. If UdpPort was changed, update the firewall rule to match - see Configure.

PDUs arrive, but a capture session never starts

Cause. With StartOnAnyPDU disabled (the default), a session only starts on a PDU whose type is in StartPduTypes (default: StartResume). A source that never sends that PDU type - for example, one that only sends EntityState traffic without ever issuing a Start/Resume - will never trigger a session under the default configuration.

Fix. Either enable StartOnAnyPDU so any valid PDU starts a session, or add the PDU types your source actually sends to StartPduTypes.

The session starts and stops repeatedly on its own

Cause. With StartOnAnyPDU enabled and StopOnSilence also enabled, a session ends after SilenceThreshold with no PDUs at all - a source that pauses between updates longer than that threshold looks identical to a source that has gone offline.

Fix. Raise SilenceThreshold to comfortably exceed the source’s normal update gaps, or disable StopOnSilence and stop the session by another means.

A known-good sender’s packets never appear

Cause. LocalCaptureOnly is enabled, and the sender is not one of the workstation’s own local IP addresses. This drop is silent - no warning is logged, and the packet is only visible as a count in droppedPackets on the debug view, indistinguishable from a packet dropped for any other reason.

Fix. Disable LocalCaptureOnly if the sender is expected to be a different host on the network, not the workstation itself.

The module never restarts after enabling then disabling it

Cause. This module runs continuously from HEAT Capture’s own startup, independent of capture sessions (see Overview) - it is not restarted or reinitialised at session boundaries the way session-scoped modules are. Its native socket only rebuilds when a socket-relevant setting (UdpPort, NetworkMode, NetworkGroupAddress) actually changes.

Fix. If the receiver appears stuck in an error state, changing one of those three settings to a genuinely different value and back forces a socket rebuild without a full application restart - setting it to the value it already holds does not, since the module only rebuilds when the new value differs from what it is currently bound to.