Skip to Content
This documentation is provided with the HEAT environment and describes this HEAT instance.

Troubleshooting the Mentalista module

The client cannot connect at all

Cause. Either the capture session is not running yet (the listener only exists while a session is active), or Port has been changed away from 5555 without also updating the workstation firewall rule this module’s network.listen capability is scoped to.

Fix. Start the capture session before connecting the client. If Port was changed, update the firewall rule to match - see Configure.

The client connects, but no predictions ever appear

Cause. In this deployment the client is Mentalista’s own web application, running in an automated Chrome session (driven via ChromeDriver) that must itself be logged into Mentalista’s cloud backend and paired with the physical headset - this module has no visibility into any of that. A browser session that opened the WebSocket but is not actually logged in, or whose headset is not connected on the Mentalista side, will sit connected here and never send a prediction event; nothing in this module’s own logs distinguishes that from a healthy idle connection.

Fix. Check the Chrome/ChromeDriver session and Mentalista backend login first - this is a peer-side problem, not something this module’s settings can fix.

The client connects but a specific prediction never appears

Cause. A prediction event that has none of the four recognised prediction paths (predictions.emotion.valence, predictions.emotion.arousal, predictions.attention.attention_index, predictions.cognitiveLoad.cognitive_index) produces no frame at all - silently, with no warning logged. Any event type other than ready, prediction, commandSuccess or commandError is also silently ignored.

Fix. Confirm the client is actually sending prediction events with at least one of the four paths populated, not only raw sensor data.

Automatic connect never succeeds

Cause. Retries only happen after an explicit commandError naming connect - a client that never responds is not retried at all, and once ConnectRetryCount retries are exhausted after repeated commandError responses, the module gives up permanently for that WebSocket session.

Fix. Check the client is actually replying to the connect command it receives. If it needs more attempts, raise ConnectRetryCount; if a slower client needs longer between attempts, raise ConnectRetryDelayMs and MaxConnectRetryDelayMs. A client that stays silent will never be retried regardless of these settings - reconnecting the WebSocket session is the only way to trigger another attempt.

The listener rejects a client immediately

Cause. The listener answers a plain HTTP request that is not a WebSocket upgrade with HTTP 400 - a health-check probe or browser hitting the URL directly will see this and nothing else.

Fix. Confirm the client is actually issuing a WebSocket upgrade request, not a plain HTTP request, on the listener’s Host:Port.