This documentation is provided with the HEAT environment and describes this HEAT instance.

Configure the Mentalista module

Settings are edited in HEAT Capture’s module settings UI, under HEAT.Mentalista.

🚫

Changing Port away from its default (5555) moves the listener outside the firewall scope HEAT Capture grants this module. The module will still try to bind the new port, but nothing guarantees the workstation firewall admits inbound connections to it. Do not change Port without also updating the host’s firewall rule for this module.

Listener

SettingTypeDefaultWhat it controls
HoststringlocalhostAddress the WebSocket listener binds to.
Portinteger5555TCP port for the listener. See the warning above before changing this.

The listener is only open while a capture session is running; it starts when the session starts and stops when the session ends.

Automatic connect

SettingTypeDefaultWhat it controls
ConnectOnStartupbooleantrueSends a connect command automatically once a client’s WebSocket session opens.
TargetDeviceBluetooth | SyntheticBluetoothWhich connect command payload to send: Bluetooth sends type M0 (the first paired Bluetooth device matching that filter); Synthetic sends type S06 (development test device).
ConnectInitialDelayMsinteger (ms)250Delay after the WebSocket opens before sending the first connect command.
ConnectRetryCountinteger3Additional retries after the first connect attempt receives a commandError. 0 disables retries.
ConnectRetryDelayMsinteger (ms)1000Delay before the first retry. Later retries double this delay each time.
MaxConnectRetryDelayMsinteger (ms)10000Upper bound the doubling retry delay never exceeds.

Retries only happen after an explicit commandError response naming connect - a client that never responds at all is not retried. See Section 4.4, Messages, of the Interface Control Document for the exact message exchange.

Entity identity and rate

SettingTypeDefaultWhat it controls
EntityIdinteger1Entity ID written into every published frame.
EntityNamestring"" (empty)Entity name. When empty, the device name reported in the connected client’s ready event is used instead; if neither is available, the entity is named mentalista.
SendAtNativeRatebooleantruetrue: each prediction event is published immediately as it arrives. false: HEAT Capture’s own per-tick poll publishes the most recently received prediction instead, once.

Host settings

This module also exposes the generic settings every HEAT Capture module has - Enabled, Interval, OverrideNodeId/NodeId, Timeout. See Manage capture modules for what each does.